Ka nānā 'ana o Antmed Invasive Blood Pressure Transducer

Ma ke kahua lapaʻau, ua hoʻonui a hoʻonui i ka manaʻo o nā kauka a hoʻonui i ka manaʻo qualitative e like me ka quantitative detection.ʻO lākou nā mea nui o nā mea hana lapaʻau a me nā mea hana.He kuleana koʻikoʻi ia ma nā ʻano hana like ʻole o ka hoʻoponopono, ka nānā ʻana a me ka hoʻoponopono.Hiki i nā mea naʻau lapaʻau ke hoʻouna i nā hōʻailona ola e like me ka neʻe ʻana, ka wikiwiki, ka haʻalulu, ke kaomi, ka kahe, ka mahana, ka bioelectricity, a me ka haku mele.

Ma o ke kaomi ʻana o ka wai, e hoʻouna ʻia ke kaomi i loko o ke kīʻaha koko i ka ʻike kaomi o waho ma o ka wai i loko o ka catheter, i mea e loaʻa ai ka nalu ikaika o ka hoʻololi ʻana i ka manawa maoli i ka moku koko.Systolic, diastolic and mean arterial pressure.

Nā Pōmaikaʻi: ʻOi aku ka pololei a me ka hilinaʻi o ke koko invasive, a ua kokoke loa i ka waiwai maʻamau ma mua o ke koko non-invasive.

ʻO ka puka ʻana o ka nanotechnology i ka hopena o ke kenekulia i hala i hiki ai ke kaʻina hana micro-machining.Ma o ke kaʻina hana micromachining, hiki ke hoʻoponopono ʻia ka mīkini paʻi kiʻi e ka mana kamepiula, a hiki ke hoʻomalu ʻia kona linearity i ka laulā o nā micrometers.Ma ka hoʻohana ʻana i kēia ʻenehana, hiki ke hana ʻia a hoʻopaʻa ʻia i nā ʻāpana micron-scale, nā ʻāpana, a me nā membrane, e hoʻokomo i ka mea ʻike kaomi i ke kahua micron.

ʻO ke kahe koko invasive a pau he mea nui loa ia i nā hana nui e like me nā lumi hana a me nā ICU a me ka hoʻopakele ʻana i nā maʻi maʻi koʻikoʻi.Loaʻa i ka manometry non-invasive nā mea maikaʻi o ka hana maʻalahi, ʻaʻohe ʻeha, a maʻalahi ka ʻae ʻana, a hoʻohana nui ʻia i ka hana lapaʻau.ʻO nā hemahema: ke kumukūʻai kiʻekiʻe, koi i nā ʻoihana i aʻo ʻia e hoʻohana.

Hoʻohana ʻia ka transducer koko invasive e hoʻopili i ka mea maʻi a me ka mea nānā, a hiki ke ana i ke kahe koko invasive o ke kino o ke kanaka, e like me ka arterial pressure, central venous pressure, pulmonary artery pressure, left coronary artery pressure, intracranial pressure, etc. , e hāʻawi i nā kuhikuhi no nā kauka e nānā i ke kūlana o ka mea maʻi.Hoʻohana nui ʻia ia i ka anesthesiology o ka haukapila, intensive care unit (ICU) a me ka cardiology/cardiac surgery.I kēia manawa, ʻo ka noi nui loa ma Kina ka ʻoihana anesthesiology o ka haukapila.Hoʻohana ʻia ka mea ʻike puʻupuʻu e like me ka nānā ʻana i ka consumable me ka anesthesia surgery, a ukali ʻia e nā lako nānā no ka ʻoki ʻana i ka naʻau a me ka angiography.ʻO ka hapa nui o nā poʻe maʻi e lawe mai i ka sensor kaomi i ke kaʻina anesthesia maʻamau i loko o ka hale ICU.

Hoʻohana ʻo Antmed invasive blood pressure transducer i ka puʻupuʻu koʻikoʻi o ka honua e ʻike i nā loli o ke koko ma ke ʻano maʻalahi, e hāʻawi ana i nā hōʻailona lapaʻau kūpono loa no nā hana lapaʻau.Loaʻa kā mākou mau mea ʻike kaomi i nā ala hoʻokahi, ʻelua, a ʻekolu.Ma ka manawa like, he ʻeiwa mau kikowaena e hoʻokō ai i nā koi o ka interface like ʻole, e like me Mindray, Edwards, Utah, BD, Argon, Philips a me nā mea hana ʻē aʻe.Ua hala ka mea hoʻokahe koko invasive i ka ISO 13485, MDSAP, CE, FDA 510K ʻae kūʻai.Hoʻopiha ʻia kā mākou mau kikoʻī transducer koko koko a me nā mea pono, mai ka hoʻoponopono ʻana i nā papa, hoʻoponopono i nā clips, hoʻoponopono ʻana i nā papa a hiki i nā kaula IBP, hiki i kā mākou mau mea ʻike ke ana i ke kahe koko, ka mimi a me nā pilikia physiological ʻē aʻe o ke kino kanaka.

ʻO kā mākou transducer blood pressure invasive he 100% hale hana i hoʻāʻo ʻia, e hōʻoiaʻiʻo ana i ka maikaʻi o kā mākou huahana.Hoʻohana nui ʻia ka Antmed disposable pressure transducer (DPT) i ka mālama koʻikoʻi a me ka anesthesia e hāʻawi ana i nā heluhelu kūlike a pololei i ka wā o ka nānā ʻana i ke koko invasive.


Ka manawa hoʻouna: ʻAukake-24-2022

Waiho i kāu memo: